LET US HELP YOU GROW
TABLE OF CONTENTS
< All Topics
Print

Display indication on Dimlux Expert MKII 600W + 1000W

If there is an error message, it will scroll across the display.

If there is a (mains) power failure (but the fixture is connected to other fixtures, “psu fail” will scroll across the display.

If there is an internal error in the electronics that drive the lamp, then “hid fail” will scroll across the display.

PSU FAIL

Meaning: No power HID PCB
Solution : Return to Dealer

HID FAIL

Meaning: No communication to HID
PCB Solution : Return to Dealer

INITIALATION

Meaning: Initalisation
Solution : –

SOFT OFF

Meaning: Lamp off by button
Solution : –

ON ANALOG

Meaning: Lamp on due exernal analog steering (Maxi Controller)
Solution : –

ANALOG OFF

Meaning: Lamp off due exernal analog steering (Maxi Controller)
Solution : –

ON DIGITAL

Meaning: Lamp on due digital ABP2 busprotocol
Solution : –

OFF DIGITAL

Meaning: Lamp off due digital ABP2 busprotocol
Solution : –

ERROR DIGITAL LOST

Meaning: Error, digital connection (ABP2) lost
Solution : Connect RJ45 cables. Firmware error

HVP ERROR HIGH VOLTAGE PROTECTION

Meaning: High voltage error
Solution : Mains voltage is to high

LVP ERROR LOW VOLTAGE PROTECTION

Meaning: Low voltage error
Solution : Main voltage is to low, or HID PCB defective

HTP ERROR HIGH TEMPERATURE PROTECTION

Meaning: High temperature error
Solution : Ballast is to hot

OCP ERROR OPEN CONTACT

Meaning: Open contact error
Solution : Lamp not connected. Wiring to lamp broken. HID PCB broken

SHORT ERROR SHORT CIRCUIT

Meaning: Shortcut error
Solution : Shortcut in lamp op lamphousing. Short between wires. HID PCB broken

EOL ERROR END OF LIVE BULB

Meaning: End of Life
Solution : Replace LAMP. HID broken

IGNITE

Meaning: Ignite.
Solution : Lamp will ignite

FREERUNNING 1000

Meaning: freerunning 1000Watt
Solution : –