Display indication (Only Dimlux Expert 315W + 630W)

Each Dimlux fixture has a self diagnosis system. The display on each unit shows error and status info.

 

Status

F-Flash = Soft off

The ballast is off because the dim button is on soft-off.

F-on = On-DB

The ballast is on, no Maxi Controller detected.

A-Flash = Off remote

The ballast is off by Maxi Controller.

A-on = on remote

The ballast is on by Maxi Controller.

1-strobo = Igniting

The ballast is igniting the lamp.

 

Error

2-On = HVP

The input voltage is too high.

3-On = LVP

The input voltage is too low.

4-On = HTP

The ballast is too hot.

5-On = Open

Open contact or lamp failure.

6-On = Short

Short in lamp circuit or lamp failure.

7-On = EOL

End-of-life. Lamp surpassed it’s service life. Maximum power connot be attained anymore.*